You copied the Doc URL to your clipboard.

Default section placement

By default, the linker places input sections in a specific order within an execution region.

The sections are placed in the following order:

  1. By attribute as follows:

    1. Read-only code.

    2. Read-only data.

    3. Read-write code.

    4. Read-write data.

    5. Zero-initialized data.

  2. By input section name if they have the same attributes. Names are considered to be case-sensitive and are compared in alphabetical order using the ASCII collation sequence for characters.

  3. By a tie-breaker if they have the same attributes and section names. By default, it is the order that armlink processes the section. You can override this with the FIRST or LAST execution region attribute.

Note

The sorting order is unaffected by ordering of section selectors within execution regions.

These rules mean that the positions of input sections with identical attributes and names included from libraries depend on the order the linker processes objects. This can be difficult to predict when many libraries are present on the command line. The --tiebreaker=cmdline option uses a more predictable order based on the order the section appears on the command line.

The base address of each input section is determined by the sorting order defined by the linker, and is correctly aligned within the output section that contains it.

The linker produces one output section for each attribute present in the execution region:

  • One RO section if the execution region contains read-only code or data.

  • One RW section if the execution region contains read-write code or data.

  • One ZI section if the execution region contains zero-initialized data.

Alternative sorting orders are available with the --sort=algorithm command-line option. The linker might change the algorithm to minimize the amount of veneers generated if no algorithm is chosen.

Example

The following scatter file shows how the linker places sections:

LoadRegion 0x8000
{
    ExecRegion1 0x0000 0x4000
    {
        *(sections)
        *(moresections)
    }
    ExecRegion2 0x4000 0x2000
    {
        *(evenmoresections)
    }
}

The order of execution regions within the load region is not altered by the linker.

Handling unassigned sections

The linker might not be able to place some input sections in any execution region.

When the linker is unable to place some input sections it generates an error message. This might occur because your current scatter file does not permit all possible module select patterns and input section selectors.

How you fix this depends on the importance of placing these sections correctly:

  • If the sections must be placed at specific locations, then modify your scatter file to include specific module selectors and input section selectors as required.

  • If the placement of the unassigned sections is not important, you can use one or more .ANY module selectors with optional input section selectors.

Was this page helpful? Yes No