You copied the Doc URL to your clipboard.

Trace Control view

Use the Trace Control view to start or stop trace capture and clear the trace buffer on a specified trace capture device.

The Trace Control view additionally displays information about the trace capture device, the trace source used, the status of the trace, and the size of the trace buffer.

Figure 15-50 Trace Control view

Trace Control view

The trace capture device and trace sources available in the trace capture device are listed on the left hand side of the view. Select any trace source to view additional information.

The following Trace Capture Device information is displayed in the view:

Trace Capture Device

The name of the trace capture device.

Capture Status

The trace capture status. On when capturing trace data, Off when not capturing trace data.

Trigger Position

The location of the trigger within the buffer.

Note

This information is only available for hardware targets.
Buffer Size

The capacity of the trace buffer.

Buffer Used

The amount of trace data currently in the buffer.

Buffer Wrapped

The trace buffer data wraparound status.

Persistent Trace

The persistent trace data status.

The following Trace Source information is displayed in the view:

Trace Source

The name of the selected trace source.

Source ID

The unique ID of the selected trace source.

Source Encoding

The trace encoding format.

Core

The core associated with the trace source.

Context IDs

The tracing context IDs availability status.

Cycle Accurate Trace

The cycle accurate trace support status.

Virtualization Extensions

The virtualization extensions availability status.

Timestamps

Timestamp availability status for the trace.

Timestamp Origin

Whether a timestamp origin for the trace is set or cleared. When set, timestamps are displayed as offsets from the origin.

Trace Triggers

Trace triggers support status.

Trace Start Points

Trace start points support status.

Trace Stop Points

Trace stop points support status.

Trace Ranges

Trace ranges support status.

Note

The information displayed varies depending on the trace source.

Trace Control view options

Start Capture

Click Start Capture to start trace capture on the trace capture device. This is the same as the trace start command.

Stop Capture

Click Stop Capture to stop trace capture on the trace capture device. This is the same as the trace stop command.

Clear Trace Buffer

Click Clear Trace Buffer to empty the trace buffer on the trace capture device. This is the same as the trace clear command.

Start trace capture when target restarts (after a stop)

Select this option to automatically start trace capture after a target restarts after a stop.

Stop trace capture when target stops

Select this option to automatically stop trace capture when a target stops.

Stop trace capture on trigger

Select this option to stop trace capture after a trace capture trigger has been hit.

Post-trigger capture size

Use this option to control the percentage of the trace buffer that should be reserved for after a trigger point is hit. The range is from 0 to 99.

Note

The trace start and trace stop commands and the automatic start and stop trace options act as master switches. Trace triggers cannot override them.

Toolbar and context menu options

The following options are available from the toolbar or context menu:

Linked: context

Links this view to the selected connection in the Debug Control view. This is the default. Alternatively you can link the view to a specific connection or processor in a Symmetric MultiProcessing (SMP) connection. If the connection you want is not shown in the drop-down list, you might have to select it first in the Debug Control view.

New Trace Control View

Select this option to open a new Trace Control view.

Refresh

Select this option to refresh the current Trace Control view.

DTSL Options…

Select this option to open the Debug and Trace Services Layer (DTSL) Configuration dialog. This dialog can be used to configure additional debug and trace settings, such as, adding, editing or choosing a DTSL connection configuration.

Trace Dump…

Select this option to open the Trace Dump dialog. In this dialog you can configure and export the raw trace data from the buffer and write it to a file.

Was this page helpful? Yes No