17.8. Miscellaneous signals

Table 17.8 shows the setup and hold times of miscellaneous signals not described in the previous sections.

Timing parameters of miscellaneous signals
SignalClockSetup parameterPercent of clock period Hold parameterPercent of clock period
nPORESETCLK[1]Tisnporeset50%Tihnporeset5%
ARESETnCLK[1]Tisaresetn50%Tiharesetn5%
ARESETNEONnCLK[1]Tisaresetneonn50%Tiharesetneonn5%
SECMONOUTENCLK[2]Tissecmonouten30%Tihsecmonouten5%
SECMONOUT[86:0]CLKTovsecmonout30%Tohsecmonout5%
STANDBYWFICLKTovstandbywfi30%Tohstandbywfi5%
nFIQCLK[3]Tisnfiq30%Tihnfiq5%
nIRQCLK[3]Tisnirq30%Tihnirq5%
VINITHICLK[2]Tisvinithi30%Tihvinithi5%
CFGTECLK[2]Tiscfgte30%Tihcfgte5%
CFGEND0CLK[2]Tiscfgend030%Tihcfgend05%
CFGNMFICLK[2]Tiscfgnmfi30%Tihcfgnmfi5%
CP15SDISABLECLKTiscp15disable30%Tihcp15disable5%
CPEXIST[13:0]CLK[2]Tiscpexist30%Tihcpexist5%
SILICONID[31:0]CLK[2]Tissiliconid30%Tihsiliconid5%
nPMUIRQCLK[3]Tovnpmuirq30%Tohnpmuirq5%

[1] This signal has multiple end-points and must be level-sensitive.

[2] Although this is a static input, it can be timed at frequency during static timing analysis.

[3] This signal has multiple end-points and must be treated as level-sensitive.