You copied the Doc URL to your clipboard.

3.1. About this programmers model

The following information applies to the registers:

  • The base address is not fixed, and can be different for any particular system implementation. The offset of each register from the base address is fixed.

  • Do not attempt to access reserved or unused address locations. Attempting to access these locations can result in Unpredictable behavior.

  • Unless otherwise stated in the accompanying text:

    • do not modify undefined register bits

    • ignore undefined register bits on reads

    • all register bits are reset to a logic 0 by a system or power-on reset.

  • Access type in Table 3.1 is described as follows:

    RW

    Read and write.

    RO

    Read only.

    WO

    Write only.

Was this page helpful? Yes No