DC IGVAC, Invalidate of Allocation Tags by VA to PoC
The DC IGVAC characteristics are:
Purpose
Invalidate Allocation Tags in data cache by address to Point of Coherency.
Configuration
This instruction is present only when FEAT_MTE is implemented and ID_AA64PFR1_EL1.MTE != 0b0001. Otherwise, direct accesses to DC IGVAC are UNDEFINED.
Attributes
DC IGVAC is a 64-bit System instruction.
Field descriptions
The DC IGVAC input value bit assignments are:
63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
Virtual address to use | |||||||||||||||||||||||||||||||
Virtual address to use | |||||||||||||||||||||||||||||||
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Bits [63:0]
Virtual address to use. No alignment restrictions apply to this VA.
Executing the DC IGVAC instruction
When the instruction is executed, it can generate a watchpoint, which is prioritized in the same way as other watchpoints. If a watchpoint is generated, the CM bit in the ESR_ELx.ISS field is set to 1.
This instruction requires write access permission to the VA, otherwise it generates a Permission Fault, subject to the constraints described in 'Permission fault'.
Execution of this instruction might require an address translation from VA to PA, and that translation might fault. For more information, see 'The data cache maintenance instruction (DC)'.
Accesses to this instruction use the following encodings:
DC IGVAC, <Xt>
op0 | op1 | CRn | CRm | op2 |
---|---|---|---|---|
0b01 | 0b000 | 0b0111 | 0b0110 | 0b011 |
if PSTATE.EL == EL0 then UNDEFINED; elsif PSTATE.EL == EL1 then if EL2Enabled() && HCR_EL2.TPCP == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif EL2Enabled() && (!HaveEL(EL3) || SCR_EL3.FGTEn == '1') && HFGITR_EL2.DCIVAC == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif EL2Enabled() && HCR_EL2.<DC,VM> != '00' then DC_CIGVAC(X[t]); else DC_IGVAC(X[t]); elsif PSTATE.EL == EL2 then DC_IGVAC(X[t]); elsif PSTATE.EL == EL3 then DC_IGVAC(X[t]);