TLBI ASIDE1, TLB Invalidate by ASID, EL1
The TLBI ASIDE1 characteristics are:
Purpose
Invalidates cached copies of translation table entries from TLBs that meet all the following requirements:
-
The entry is a stage 1 translation table entry.
-
The entry would be used for the specified ASID, and either:
-
Is from a level of lookup above the final level.
-
Is a non-global entry from the final level of lookup.
-
-
When EL2 is implemented and enabled in the Security state described by the current value of SCR_EL3.NS:
-
When EL2 is not implemented or is disabled in the current Security state, the entry would be required to translate an address using the EL1&0 translation regime.
The invalidation applies to the PE that executes this System instruction.
Configuration
There are no configuration notes.
Attributes
TLBI ASIDE1 is a 64-bit System instruction.
Field descriptions
The TLBI ASIDE1 input value bit assignments are:
63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
ASID | RES0 | ||||||||||||||||||||||||||||||
RES0 | |||||||||||||||||||||||||||||||
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
ASID, bits [63:48]
ASID value to match. Any appropriate TLB entries that match the ASID values will be affected by this System instruction.
If the implementation supports 16 bits of ASID, then the upper 8 bits of the ASID must be written to 0 by software when the context being invalidated only uses 8 bits.
Bits [47:0]
Reserved, RES0.
Executing the TLBI ASIDE1 instruction
Accesses to this instruction use the following encodings:
TLBI ASIDE1{, <Xt>}
op0 | op1 | CRn | CRm | op2 |
---|---|---|---|---|
0b01 | 0b000 | 0b1000 | 0b0111 | 0b010 |
if PSTATE.EL == EL0 then UNDEFINED; elsif PSTATE.EL == EL1 then if EL2Enabled() && HCR_EL2.TTLB == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif EL2Enabled() && (!HaveEL(EL3) || SCR_EL3.FGTEn == '1') && HFGITR_EL2.TLBIASIDE1 == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif EL2Enabled() && HCR_EL2.FB == '1' then TLBI_ASIDE1IS(X[t]); else TLBI_ASIDE1(X[t]); elsif PSTATE.EL == EL2 then TLBI_ASIDE1(X[t]); elsif PSTATE.EL == EL3 then TLBI_ASIDE1(X[t]);