You copied the Doc URL to your clipboard.
TRCIDR10, ID Register 10
The TRCIDR10 characteristics are:
Purpose
Returns the tracing capabilities of the trace unit.
Configuration
AArch64 System register TRCIDR10 bits [31:0] are architecturally mapped to External register TRCIDR10[31:0] .
This register is present only when FEAT_ETE is implemented. Otherwise, direct accesses to TRCIDR10 are UNDEFINED.
Attributes
TRCIDR10 is a 64-bit register.
Field descriptions
The TRCIDR10 bit assignments are:
63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
RES0 | |||||||||||||||||||||||||||||||
NUMP1KEY | |||||||||||||||||||||||||||||||
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Bits [63:32]
Reserved, RES0.
NUMP1KEY, bits [31:0]
When TRCIDR0.TRCDATA != 0b00:
When TRCIDR0.TRCDATA != 0b00:
Indicates the number of P1 right-hand keys. Data tracing is not implemented in ETE and this field is reserved for other trace architectures. Allocated in other trace architectures.
Otherwise:
Otherwise:
Reserved, RES0.
Accessing the TRCIDR10
Accesses to this register use the following encodings:
MRS <Xt>, TRCIDR10
op0 | op1 | CRn | CRm | op2 |
---|---|---|---|---|
0b10 | 0b001 | 0b0000 | 0b0010 | 0b110 |
if PSTATE.EL == EL0 then UNDEFINED; elsif PSTATE.EL == EL1 then if Halted() && HaveEL(EL3) && EDSCR.SDD == '1' && boolean IMPLEMENTATION_DEFINED "EL3 trap priority when SDD == '1'" && CPTR_EL3.TTA == '1' then UNDEFINED; elsif CPACR_EL1.TTA == '1' then AArch64.SystemAccessTrap(EL1, 0x18); elsif EL2Enabled() && CPTR_EL2.TTA == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif EL2Enabled() && (!HaveEL(EL3) || SCR_EL3.FGTEn == '1') && HDFGRTR_EL2.TRCID == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif HaveEL(EL3) && CPTR_EL3.TTA == '1' then if Halted() && EDSCR.SDD == '1' then UNDEFINED; else AArch64.SystemAccessTrap(EL3, 0x18); else return TRCIDR10; elsif PSTATE.EL == EL2 then if Halted() && HaveEL(EL3) && EDSCR.SDD == '1' && boolean IMPLEMENTATION_DEFINED "EL3 trap priority when SDD == '1'" && CPTR_EL3.TTA == '1' then UNDEFINED; elsif CPTR_EL2.TTA == '1' then AArch64.SystemAccessTrap(EL2, 0x18); elsif HaveEL(EL3) && CPTR_EL3.TTA == '1' then if Halted() && EDSCR.SDD == '1' then UNDEFINED; else AArch64.SystemAccessTrap(EL3, 0x18); else return TRCIDR10; elsif PSTATE.EL == EL3 then if CPTR_EL3.TTA == '1' then AArch64.SystemAccessTrap(EL3, 0x18); else return TRCIDR10;