5.1. Non-standard signals

Table 4 lists the signals that are present on the downsizer, but that the AMBA AXI Protocol Specification does not describe.

Non-standard signals
NameType

Source/destination

Description
SCANENABLEInputScan logicScan mode enable
SCANINACLKInputScan logicScan chain input
SCANOUTACLKOutputScan logicScan chain output

Note

The signals that Table 4 does not list are standard AMBA AXI signals that the AMBA AXI Protocol Specification describes. The signal names are appended with:

  • the letter M for signals that connect to the component master interface

  • the letter S for signals that connect to the component slave interface.