5. Signal descriptions

Figure 3 shows the AXI upwards-synchronizing bridge signal connections.

Figure 3. Upwards-synchronizing bridge signal connections

Figure 3. Upwards-synchronizing bridge signal
connections

Note

In Figure 3:

  • The read channel, write channel, and low-power interface signals are standard AMBA AXI signals that the AMBA AXI Protocol Specification describes. The signal names are appended with:

    • the letter M for signals that connect to the component master interface

    • the letter S for signals that connect to the component slave interface.

  • The scan signals are not shown.

Table 4 lists the non-standard AXI and scan signals.

Non-standard AXI and scan signals
NameType

Source/ destination

Description
ACLKMInputClock sourceClock signal from the faster clock domain
ACLKSELInputClock sourceSelect signal that indicates relationship between fast and slow clocks
ARUSERMOutputScan logicAR channel user sideband signal to the fast clock domain
ARUSERSInputScan logicAR channel user sideband signal from the slow clock domain
AWUSERMOutputScan logicAW channel user sideband signal to the fast clock domain
AWUSERSInputScan logicAW channel user sideband signal from the slow clock domain
SCANENABLEInputScan logicScan mode enable
SCANINACLKMInputScan logicScan chain clock input
SCANOUTACLKMOutputScan logicScan chain clock output
WUSERMOutputScan logicAW channel user sideband signal to the fast clock domain
WUSERSInputScan logicAW channel user sideband signal from the slow clock domain