Capture & Analysis Options dialog box settings

The Capture & Analysis Options dialog box enables you to change the capture session settings, including the IP address of the target, duration, sample rate, and buffer size.

To open it, click the Capture & Analysis Options button () in the Streamline Data view.

Figure 3-1 Capture & Analysis Options dialog box

Capture & Analysis Options dialog box

Connection

The Connection section contains the following settings:

Address
The IP address of the target. You can alternatively enter the network name of your target. The value that is given in this field overwrites the value in the Address field of the Streamline Data view, if one has been given. The reverse is also true. If you enter a new address in the Address field of the Streamline Data view, it replaces the value that was entered here.

Note

  • By default, Streamline uses port 8080 to connect to a target. To use a different port, specify one here by entering a colon and a port number after the IP address. For example, enter Your_IP_address:1010 to use port 1010 to connect to the target.

  • If you use the port forwarding of Android ADB with USB, enter localhost in the Address field.

Browse for a target button ()
The Browse for a target button, on the right side of the Address field, opens the Connection Browser. Streamline searches your network and produces a list of possible targets. Selecting one populates the Address field.
ADB Path
The location of the ADB or SDB executable. You must specify this location in order for the Connection Browser and the Setup Target... dialogs to list Android targets that are connected using ADB or Tizen targets that are connected using SDB.

Capture

The Capture section contains the following options:

Sample Rate
The target generates periodic measurement interrupts according to the following settings: Normal=1kHz, Low=100Hz, and None. The Normal setting works well in most cases. Low is recommended if you have a slow target, or if the target is heavily loaded, because it means less intrusion by Streamline. The Low setting requires a longer capture to collect representative data. Set Sample Rate to None to ensure that Streamline has the lowest level of intrusion on your code, but this also means that resulting reports show only zeroes in any report columns that rely on sampling. Enabling event-based sampling for a counter overrides this timer-based sampling.
Buffer Mode

The default setting is Streaming, which enables unbounded streaming of target data directly to your host using a 1MB buffer. You can also use one of the following store-and-forward buffers:

Mode

Buffer size

Large

16MB

Medium

4MB

Small

1MB

If you select one of these sizes, the capture ends when the buffer is full, which prevents the intrusion that is caused by streaming data from the target to the host.

Note

You must set the Buffer Mode to Streaming to enable Live view. If you select one of the buffer sizes, Live view does not display real-time data during the capture session.
Call Stack Unwinding
Select this checkbox to ensure that Streamline records call stacks. This option greatly improves the visibility of the behavior of the target, but increases the amount of raw data Streamline sends from the target to the host. Ensure that you compile your EABI images and libraries with frame pointers enabled using the -fno-omit-frame-pointer compiler option. If GCC is compiled with the --with-mode=thumb option, you must also use the -marm option.

Note

  • Streamline supports call stack unwinding for ARM binaries created using GCC or ARM Compiler 6 (armclang), provided you compile them with frame pointers enabled. Streamline does not support call stack unwinding for code that is generated by ARM Compiler 5 and earlier (armcc).

  • User space gator does not support call stack unwinding.

Discard Data

If this option is enabled, Streamline discards all data when you terminate the capture. Use this option if you only want to see the data that streams during a capture session and do not want to generate a capture.

If you select this option, the Stop capture and analyze button in the Live view is disabled.

Duration
The length of the capture session, in minutes and seconds. For example, enter 1:05 for 1 minute and 5 seconds. If you do not provide a value here, the capture session continues until you stop it manually, or the buffer is full.
Use more efficient Ftrace collection

When this option is selected, Streamline uses a more efficient way of collecting ftrace, atrace, and ttrace counters. Charts that rely on these counters are empty in Live view, although the data is present when you view the report.

To use the following Command settings, you must use the -a option when starting gatord:

Working Directory
The absolute path of the directory on the target in which to run the command that is specified in the Command field.
User Name
The user account to run the command as.
Command
A command to run on the target. The command is run a few seconds after the capture begins. The capture is not automatically terminated when the command finishes.

Energy Capture

The following settings define your energy capture device:

Energy Capture drop-down menu
This menu has three options. Select No Energy Data Collection to turn energy capture off. When you select this option, all other energy capture options are disabled. Select ARM Energy Probe or NI DAQ to match your energy capture hardware.
Device

Use this field to give Streamline the name of your target energy capture device. Streamline attempts to auto-detect your device if this field is left blank.

When using ARM Energy Probe on Linux, enter /dev/ttyACM0 in the Device field, if required.

When using NI DAQ, the device name depends on the drivers that are installed on the host. For example, when using NI DAQmx Base drivers, the device name is usually Dev1. You can determine the device name by using the National Instruments List Devices utility.

Port
The port Streamline uses to communicate with your chosen energy capture device. The default port is 8081.
Tool Path
Use this field to define the path to the caiman executable, which is required to use either the ARM® Energy Probe or a NI DAQ device to gather power output statistics. The button to the right of this field enables you to search your file system.

In addition to the settings that define your capture device, the Energy Probe section has configuration options that apply to each channel:

Energy
When enabled, Streamline collects energy data for this channel in joules.
Power
When enabled, Streamline collects power data for this channel in watts.
Voltage
When enabled, Streamline collects voltage data for this channel in volts.
Current
When enabled, Streamline collects current data for this channel in amps.
Resistance
Use this field to define the value, in milliohms, of the shunt resistor that connects to each of the available channels. The default setting is 20 milliohms.

Analysis

The Analysis section contains the following controls:

Process Extra Debug Information (when available) checkbox
If you enable this option, Streamline processes DWARF debug information and line numbers. This option provides a higher level of detail in your captures, but results in higher memory usage. It does not affect the data that is collected during the capture session. It only affects the report data that is automatically generated after the termination of the capture session. This option can be changed when you re-analyze the stored capture.

Note

  • To enable this feature, you must have built the image using the -g compiler option.

  • If you disable this feature, the source section of the Code view does not display the source code or source code statistics. The disassembly is still available with this option disabled, but the source section shows only a No source available message.

High Resolution Timeline checkbox

If you select this checkbox, Streamline processes more data, enabling you to zoom in further in the Timeline view. By default, the highest resolution in the Timeline view is milliseconds, but with this option enabled, you can zoom in to microsecond bin sizes.

This option does not affect the data that is collected during the capture session. It only affects the report data that is automatically generated after the termination of the capture session. This option can be changed when you re-analyze the stored capture data.

MGD Mode

The MGD Mode section contains the following settings:

MGD Installation Directory
The location of the Mali Graphics Debugger (MGD) application. Specify to allow MGD to be launched from Live view when the application is not currently running.
Continue live capture after MGD is activated
Select to instruct Streamline to continue displaying the live capture of data after MGD launches and begins tracing. Otherwise the Live view in Streamline is stopped.

Program Images

Use this area to explore your file system and define the images and libraries that you want to profile.

The images that you define here do not affect the data that is collected during the capture session. They only affect the report data that is automatically generated after the termination of the capture session. These images can be changed when you re-analyze the stored capture.

Note

  • When compiling images on your host, ensure that you use the -g compiler option to enable debug symbols.

  • Disabling inlining with the -fno-inline compiler option substantially improves the call path quality.

  • As an alternative to manually selecting images and libraries on the host in the Program Images section, Streamline supports automatic image transfer. To use this feature, specify a regex in the Live view. Streamline automatically transfers images whose name matches the regex, and optionally any libraries that are used by them, from the target to the host.

    If you manually select an image in the Program Images section and also specify a regex that matches an image with the same name, the image that is specified manually is used.

The following buttons are included in the Program Images section:

Add ELF Image...
Opens a file system dialog box that you can use to choose images to add. Select the image, executable, or Android Package File (APK) and click Open to add the file to the list.
Toggle Symbol Loading
Activates or deactivates symbol loading for the selected image, executable, or APK. An eye appears next to any entry in the list with symbol loading turned on.

Figure 3-2 Symbols loaded icon

Symbols loaded icon

Using this option instead of removing an entry from the list makes it easy to toggle an entry on and off over multiple runs, as it does not remove it from the Program Images list.
Remove
Removes the selected entries.
Import
Use the resulting file system dialog box to find an existing session.xml file and import its settings to the Capture & Analysis Options dialog box.
Export
Saves the current settings as a session.xml file.
Save
Saves the settings and exits.
Cancel
Discards all changes and exits.